Items : %s%s
AC Fans
Factory Lead Time
- 15 Weeks
- 16 Weeks
- 20 Weeks
Feature
- Temperature Sensor
Housing Material
- Aluminium
Material
- Aluminium
- Metal
- Plastic
Material - Blade
- Polybutylene Terephthalate (PBT)
Material - Frame
- Aluminum
Max Operating Temperature
- 158°C
- 176°C
Min Operating Temperature
- -40°C
- -4°C
- 14°C
Moisture Sensitivity Level (MSL)
- 1 (Unlimited)
Mount
- Flanges
Operating Temperature
- -40~158°F -40°C~70°C
- -4~176°F -20°C~80°C
- 14~149°F -10°C~65°C
- 14~158°F -10°C~70°C
- 14~176°F -10°C~80°C
Package / Case
- Axial
Packaging
- Box
Part Status
- Active
Published
- 2006
- 2008
- 2009
- 2010
Series
- 8000N
- OA109
- OA172AP
- OA172SAP
- OA172SAPL
- OA254
- OA80
Size / Dimension
- Rectangular/Rounded - 172mm Lx150mm H
- Round - 172mm Dia
- Round - 254mm Dia
- Square - 119.5mm Lx119.5mm H
- Square - 120mm Lx120mm H
- Square - 60mm Lx60mm H
- Square - 80mm Lx80mm H
Termination
- 2 Terminals
- 2 Wire Leads
Weight
- 1.1lbs 499.0g
- 1.2lbs 544.3g
| Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Datasheet | Factory Lead Time | Mount | Housing Material | Packaging | Published | Series | Pbfree Code | Part Status | Moisture Sensitivity Level (MSL) | Termination | Max Operating Temperature | Min Operating Temperature | Depth | Operating Supply Voltage | Diameter | Length | RoHS Status | Lead Free | Voltage - Rated | Current Rating | Radiation Hardening | Package / Case | REACH SVHC | Frequency | Height | Width | Approval Agency | Weight | Operating Temperature | Size / Dimension | Voltage Range | Ratings | Voltage - Rated AC | Ingress Protection | Power Rating | Max Power Dissipation | Feature | Current Rating (Amps) | Lifetime @ Temp | Life (Hours) | Power Consumption | Air Flow | Power (Watts) | Material - Frame | Material - Blade | RPM | Bearing Type | Fan Type | Noise | Static Pressure | Thermal Support Device Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
OA109AP22-3WBR | Orion Fans | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 15 Weeks | Aluminium | 2009 | OA109 | Active | 1 (Unlimited) | 2 Wire Leads | ROHS3 Compliant | 230VAC | Axial | 120mm | cURus, TUV | -4~176°F -20°C~80°C | Square - 119.5mm Lx119.5mm H | 160V~260VAC | 12W | 12W | Reverse Air Flow | 60000 Hrs @ 40°C | 75.0 CFM (2.10m3/min) | 12.00W | Aluminum | Polybutylene Terephthalate (PBT) | 2300 RPM | Ball | Tubeaxial | 38.0 dB | 0.160 in H2O (39.8 Pa) | |||||||||||||||||||||||||
![]() |
FAA1-12038QSHW31-A | Qualtek | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | 20 Weeks | 2013 | FAA1-12038 | Active | 1 (Unlimited) | 2 Wire Leads | ROHS3 Compliant | 230VAC | 90mA | Axial | 119.5mm | CE, cURus, TUV | 1.2lbs 544.3g | 14~140°F -10°C~60°C | Square - 119.5mm Lx119.5mm H | 14.8W | 0.090A | 97.0 CFM (2.72m3/min) | 14.80W | Aluminum | Plastic | 2900 RPM | Sleeve | Tubeaxial | 44.5 dB(A) | 0.350 in H2O (87.2 Pa) | ||||||||||||||||||||||||||||
![]() |
R3G310-AJ40-71 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | 8 Weeks | Panel | Aluminium | R3G310 | Active | Not Applicable | 3 Wire Leads with Ferrules, 5 Wire Leads with Ferrules | 318mm | RoHS Compliant | 230VAC | 2.9A | No | 200 | 5.06kHz | 167.1mm | CCC, CE, CSA, EAC, UL | -13~86°F -25°C~30°C | Round - 318mm Dia | 200V~277VAC | 200V | IP54 - Dust Protected, Water Resistant | 485W | Alarm, PWM Control, Thermal Overload Protector (TOP) | 2.90A | 1180.9 CFM (33.07m3/min) | Aluminum | 2430 RPM | Ball | Motorized Impellers | |||||||||||||||||||||||||
![]() |
UF318AAA12-H1C4A-CC | Mechatronics Fan Group | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 12 Weeks | 2015 | UF318AAA | Active | Not Applicable | 2 Wire Leads | RoHS Compliant | 115VAC | CE, cUL, TUV, UL | 8.3lbs 3.8kg | -4~158°F -20°C~70°C | Round - 318mm Dia | Conformal Coating, Permanent Split Capacitor Motor, Thermal Overload Protector (TOP) | 1.43A | 1165.0 CFM (32.62m3/min) | 160W | Steel | 1580 RPM | Ball | Motorized Impellers | 66.0 dB(A) | 1.600 in H2O (398.6 Pa) | |||||||||||||||||||||||||||||||
![]() |
G2E120-CR21-01 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | Flanges | G2E120 | Active | 1 (Unlimited) | 2 Wire Leads | 110mm | 230V | 120mm | RoHS Compliant | Lead Free | 230VAC | No | 120 | No SVHC | 60Hz | 180mm | CCC, CE, GOST | 4.2lbs 1.9kg | Rectangular/Rounded - 171mm Lx180mm H | 83W | 100W | 150.0 CFM (4.20m3/min) | Aluminum | Steel | 2050 RPM | Ball | Blower, Centrifugal | 63.0 dB(A) | AC BLOWER | |||||||||||||||||||||||
![]() |
OA172AP-22-1TB1855 | Orion Fans | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 17 Weeks | Aluminium | 2013 | OA172AP | Active | 1 (Unlimited) | 2 Terminals | ROHS3 Compliant | 230VAC | Axial | 150mm | cURus | 3lbs 1.4kg | -22~176°F -30°C~80°C | Round - 172mm Dia | 200V~240VAC | IP55, Water Resistant | IP55 - Dust Protected, Water Resistant | 35W | 42W | 50000 Hrs @ 55°C | 50000 hours | 215.0 CFM (6.02m3/min) | 42.00W | Aluminum | Metal | 3200 RPM | Ball | Tubeaxial | 59.0 dB(A) | 0.510 in H2O (127.0 Pa) | ||||||||||||||||||||||
![]() |
OA180APL-22-1TB | Orion Fans | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 15 Weeks | Aluminium | Box | 2011 | OA180APL | Active | 1 (Unlimited) | 2 Terminals | ROHS3 Compliant | Lead Free | 230VAC | Axial | 180mm | cURus, TUV | -4~176°F -20°C~80°C | Square - 180mm Lx180mm H | 120V~260VAC | 70W | 70W | 60000 Hrs @ 40°C | 405.0 CFM (11.34m3/min) | 70.0W | Aluminum | Polybutylene Terephthalate (PBT) | 3300 RPM | Ball | Tubeaxial | 60.0 dB | 0.830 in H2O (206.7 Pa) | ||||||||||||||||||||||||
![]() |
11925PB-B4L-EP-00 | NMB Technologies Corporation | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 18 Weeks | 2013 | PB | Active | 1 (Unlimited) | 2 Terminals | RoHS Compliant | 240VAC | 80mA | 0.8lb 362.87g | 14~158°F -10°C~70°C | Square - 119mm Lx119mm H | 13W | 0.080A | 50000 Hrs @ 25°C | 70.6 CFM (1.98m3/min) | 13.00W | Aluminum | Polycarbonate (PC), Fiberglass Reinforced | 2700 RPM | Ball | Tubeaxial | 38.0 dB | 0.165 in H2O (41.1 Pa) | |||||||||||||||||||||||||||||
![]() |
R2E250-RA50-14 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | R2E250 | Active | Not Applicable | 4 Wire Leads with Splice Terminals | Non-RoHS Compliant | 230VAC | CCC, CSA, UL | -13~86°F -25°C~30°C | Round - 250mm Dia | IP44 | Capacitor, Thermal Overload Protector (TOP) | 1.27A | 300W | Polyamide (PA66), Nylon 6/6, Fiberglass Reinforced | 2450 RPM | Ball | Motorized Impellers | |||||||||||||||||||||||||||||||||||||
![]() |
UF12A12-STHR | Mechatronics Fan Group | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 12 Weeks | 2005 | UF12A | Active | 1 (Unlimited) | 2 Terminals | RoHS Compliant | 115VAC | 38.00mm | CE, cUL, TUV, UL | 1.2lbs 544.3g | -40~158°F -40°C~70°C | Square - 120mm Lx120mm H | 0.160A | 50000 Hrs @ 25°C | 106.0 CFM (2.97m3/min) | 12.00W | Aluminum | Polybutylene Terephthalate (PBT) | 3100 RPM | Sleeve | Tubeaxial | 46.0 dB(A) | 0.350 in H2O (87.2 Pa) | |||||||||||||||||||||||||||||
![]() |
OAB190-11-1 | Orion Fans | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 15 Weeks | Aluminium | OAB190 | Active | 1 (Unlimited) | 2 Wire Leads | 120V | ROHS3 Compliant | Lead Free | 120VAC | 540mA | 190mm | cURus, TUV | -40~140°F -40°C~60°C | Round - 190mm Dia | 100V~125VAC | 65W | 65W | 0.540A | 40000 Hrs @ 40°C | 370.0 CFM (10.36m3/min) | 65.0W | Aluminum | Thermoplastic | 2700 RPM | Ball | Motorized Impellers | 63.0 dB | 1.200 in H2O (298.9 Pa) | ||||||||||||||||||||||||
![]() |
A2S130-AA03-31 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | 20 Weeks | A2S130 | Active | Not Applicable | RoHS Compliant | 230VAC | Axial | Round - 138.3mm Dia | IP20 | Thermal Overload Protector (TOP) | 39.00W | Steel | 3250 RPM | Ball | Tubeaxial | 0.482 in H2O (120.0 Pa) | ||||||||||||||||||||||||||||||||||||||
![]() |
UF190APA12-H1C2A-B1 | Mechatronics Fan Group | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 12 Weeks | 2015 | UF190APA | Active | 1 (Unlimited) | 3 Wire Leads | RoHS Compliant | 115VAC | 70.00mm | CE, cUL, TUV, UL | 2.7lbs 1.2kg | -40~122°F -40°C~50°C | Round - 190mm Dia | Permanent Split Capacitor Motor, Speed Sensor (Tach), Thermal Overload Protector (TOP) | 0.540A | 370.0 CFM (10.36m3/min) | 65.0W | Aluminum | Polyamide (PA), Nylon | 2700 RPM | Ball | Motorized Impellers | 63.0 dB(A) | 1.200 in H2O (298.9 Pa) | |||||||||||||||||||||||||||||
![]() |
LPH15P99-BWHR-B1 | Mechatronics Fan Group | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 14 Weeks | LPH15P99 | Active | 1 (Unlimited) | 3 Wire Leads | RoHS Compliant | 100V~240VAC | 1.6lbs 725.7g | Rectangular/Rounded - 172mm Lx152mm H | 90V~264VAC | Auto Restart, Electronic Commutation (EC), Speed Sensor (Tach) | 0.200A | 228.0 CFM (6.38m3/min) | 22.50W | Aluminum | Plastic | 3200 RPM | Ball | Tubeaxial | 55.0 dB(A) | 0.600 in H2O (149.5 Pa) | ||||||||||||||||||||||||||||||||
![]() |
ASEN922519 | Panasonic Industrial Automation Sales | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | Obsolete | 1 (Unlimited) | ||||||||||||||||||||||||||||||||||||||||||||||||||||
![]() |
11938MB-B0N-EP-00 | NMB Technologies Corporation | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 18 Weeks | 2013 | MS | Active | 1 (Unlimited) | 2 Terminals | RoHS Compliant | 200VAC | 1.2lbs 544.3g | 14~158°F -10°C~70°C | Square - 119mm Lx119mm H | Thermal Overload Protector (TOP) | 0.120A | 100000 Hrs @ 25°C | 102.4 CFM (2.87m3/min) | 13.00W | Aluminum | Polycarbonate (PC), Fiberglass Reinforced | 2900 RPM | Ball | Tubeaxial | 41.0 dB | 0.310 in H2O (77.2 Pa) | ||||||||||||||||||||||||||||||
![]() |
3115PS-24T-B10-A00 | NMB Technologies Corporation | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 18 Weeks | Aluminium | 2009 | PS | Active | 1 (Unlimited) | 2 Terminals | 80mm | RoHS Compliant | 240VAC | 55mA | No | Axial | 38mm | CE, CSA, TUV, UL, VDE | 0.595lb 269.89g | 14~158°F -10°C~70°C | Square - 80mm Lx80mm H | 6W | 0.055A | 50000 Hrs @ 25°C | 21.6 CFM (0.605m3/min) | 6.00W | Aluminum | Polycarbonate (PC), Fiberglass Reinforced | 2150 RPM | Ball | Tubeaxial | 26.0 dB | 0.102 in H2O (25.4 Pa) | |||||||||||||||||||||||
![]() |
OA172AP-11-1TB | Orion Fans | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 15 Weeks | Aluminium | Box | 2008 | OA172AP | Active | 1 (Unlimited) | 2 Terminals | 51mm | 115V | 172mm | ROHS3 Compliant | Lead Free | 115VAC | Axial | 150mm | cURus, TUV | -40~158°F -40°C~70°C | Round - 172mm Dia | 80V~130VAC | 35W | 35W | 60000 Hrs @ 40°C | 35W | 235.0 CFM (6.58m3/min) | 35.00W | Aluminum | Polybutylene Terephthalate (PBT) | 3200 RPM | Ball | Tubeaxial | 52.0 dB | 0.700 in H2O (174.4 Pa) | ||||||||||||||||||||
![]() |
FAA1-12038QHLW31-A | Qualtek | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | 20 Weeks | 2013 | FAA1-12038 | Active | 1 (Unlimited) | 2 Wire Leads | ROHS3 Compliant | 230VAC | 50mA | Axial | 119.5mm | CE, cURus, TUV | 1.2lbs 544.3g | 14~158°F -10°C~70°C | Square - 119.5mm Lx119.5mm H | 9.4W | 0.050A | 71.5 CFM (2.00m3/min) | 9.40W | Aluminum | Plastic | 2200 RPM | Hydrodynamic | Tubeaxial | 37.9 dB(A) | 0.100 in H2O (24.9 Pa) | ||||||||||||||||||||||||||||
![]() |
UM12A23-STHR | Mechatronics Fan Group | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | UM12A | Obsolete | 1 (Unlimited) | 2 Terminals | 230VAC | 38.00mm | CE, cUL, TUV, UL | -40~158°F -40°C~70°C | Square - 120mm Lx120mm H | Sleeve | |||||||||||||||||||||||||||||||||||||||||||
![]() |
4715MS-23T-B1A-A00 | NMB Technologies Corporation | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 18 Weeks | 2011 | MS | Active | 1 (Unlimited) | 2 Terminals | RoHS Compliant | 230VAC | 45mA | Axial | CE, CSA, TUV, UL, VDE | 1.2lbs 544.3g | 14~158°F -10°C~70°C | Square - 119mm Lx119mm H | 6W | 0.045A | 50000 Hrs @ 25°C | 50000 hours | 49.4 CFM (1.38m3/min) | 6.00W | Aluminum | Polycarbonate (PC), Fiberglass Reinforced | 1450 RPM | Ball | Tubeaxial | 28.0 dB | 0.059 in H2O (14.7 Pa) | ||||||||||||||||||||||||||
![]() |
UF9439CBP23H-L | Mechatronics Fan Group | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 12 Weeks | 2011 | UF9439 | Active | 1 (Unlimited) | 2 Wire Leads | RoHS Compliant | 230VAC | 125.0mm | CE, TUV | 7.7lbs 3.5kg | -40~158°F -40°C~70°C | Rectangular - 510mm Lx130mm H | Permanent Split Capacitor Motor, Thermal Overload Protector (TOP) | 0.220A | 318.0 CFM (8.90m3/min) | 50.0W | Steel | Aluminum | 1600 RPM | Ball | Blower, Cross Flow | 53.0 dB(A) | 0.180 in H2O (44.8 Pa) | |||||||||||||||||||||||||||||
![]() |
5915PC-20T-B30-B00 | NMB Technologies Corporation | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 18 Weeks | Aluminium | 2004 | PC | Active | 1 (Unlimited) | 2 Terminals | 172mm | 200V | RoHS Compliant | Lead Free | 200VAC | 210mA | No | Axial | Unknown | 38mm | CE, CSA, UL, VDE | 1.8lbs 816.5g | 14~158°F -10°C~70°C | Rectangular/Rounded - 172mm Lx150mm H | 33W | 0.210A | 50000 Hrs @ 25°C | 50000 hours | 212.0 CFM (5.94m3/min) | 33.00W | Aluminum | Polycarbonate (PC), Fiberglass Reinforced | 3200 RPM | Ball | Tubeaxial | 56.0 dB | 0.865 in H2O (215.6 Pa) | |||||||||||||||||||
![]() |
G3G146-AB54-01 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 8 Weeks | Flanges | Aluminium | Bulk | G3G146 | Active | Not Applicable | 3 Wire Leads with Ferrules, 4 Wire Leads with Ferrules | 227mm | RoHS Compliant | 230VAC | No | 5.06kHz | 248.5mm | CCC, CSA, EAC, UL | -13~140°F -25°C~60°C | Rectangular/Rounded - 227mm Lx248.5mm H | 200V~277VAC | IP44 | 175W | Electronic Commutation (EC), PWM Control, Speed Sensor (Tach), Thermal Overload Protector (TOP) | 1.10A | Aluminum | Steel | 2520 RPM | Ball | Blower, Centrifugal | ||||||||||||||||||||||||||
![]() |
R2E190-RA50-21 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | 20 Weeks | External | Plastic | RadiCal® R2E190RA | yes | Active | 1 (Unlimited) | 4 Wire Leads | 115V | ROHS3 Compliant | 115VAC | No SVHC | UL | 2.6lbs 1.2kg | -13~167°F -25°C~75°C | Round - 190mm Dia | 100V~130VAC | IP44 | 70W | 70W | 341.4 CFM (9.56m3/min) | 70.0W | Polybutylene Terephthalate (PBT) | Polyamide (PA), Nylon, Fiberglass Reinforced | 2450 RPM | Ball | Motorized Impellers | ||||||||||||||||||||||||||
![]() |
RD25S-4/206198 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | Flanges | RD25S | Obsolete | 1 (Unlimited) | 2 Wire Leads | RoHS Compliant | Lead Free | 115VAC | No | 60Hz | 448mm | 44lbs 20kg | Rectangular - 404mm Lx448mm H 250mm Dia | 1.8kW | 1.8kW | 2800.0 CFM (78.40m3/min) | 1800W | Steel | Ball | Blower, Centrifugal | |||||||||||||||||||||||||||||||||
![]() |
W3G800-GV10-19F | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | Green Tech W3G800 | Active | 1 (Unlimited) | 140°C | -13°C | ROHS3 Compliant | 240VAC | 7.8A | 307.0mm | UL | 112lbs 50.8kg | -13~140°F -25°C~60°C | Square - 970mm Lx970mm H | 200V~240VAC | IP54, Water Resistant | IP54 - Dust Protected, Water Resistant | 2.86kW | Electronic Commutation (EC) | 7.8A | 16450 CFM (460.6m3/min) | 2860W | Aluminum | Aluminum | 1090 RPM | Tubeaxial | ||||||||||||||||||||||||||||
![]() |
RH35M-6/202667 | ebm-papst Inc. | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | download | RH35M | Obsolete | 1 (Unlimited) | 2 Wire Leads | RoHS Compliant | Lead Free | 230VAC | 16lbs 7.3kg | Round - 365mm Dia | 130W | 130W | 1100.0 CFM (30.80m3/min) | Steel | Ball | Motorized Impellers | 59.0 dB(A) | |||||||||||||||||||||||||||||||||||||
![]() |
FDA2-17255NBHT3F | Qualtek | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | 16 Weeks | 2014 | HPLC, FDA2-17255 | Active | 1 (Unlimited) | 2 Terminals | ROHS3 Compliant | 115VAC | 210mA | CE, cURus, TUV | 1.8lbs 816.5g | -4~158°F -20°C~70°C | Rectangular/Rounded - 172mm Lx151mm H | IP54, Water Resistant | IP54 - Dust Protected, Water Resistant | 25W | 0.210A | 50000 Hrs @ 25°C | 240.0 CFM (6.72m3/min) | 25.00W | Aluminum | Plastic | 3100 RPM | Ball | Tubeaxial | 61.0 dB(A) | 0.531 in H2O (132.3 Pa) | |||||||||||||||||||||||||||
![]() |
FAA1-12038NBJT31-A | Qualtek | 0.0000 |
Min: 1 Mult: 1 |
0.00000000 | 21 Weeks | Plastic | 2013 | FAA1-12038 | Active | 1 (Unlimited) | 2 Terminals | 158°C | 14°C | 119.5mm | ROHS3 Compliant | 115VAC | 220mA | Axial | 119.5mm | 38.50mm | CE, cURus, TUV | 1.2lbs 544.3g | 14~158°F -10°C~70°C | Square - 119.5mm Lx119.5mm H | 20.4W | 17.2W | 0.220A | 103.5 CFM (2.90m3/min) | 17.20W | Aluminum | Plastic | 3100 RPM | Ball | Tubeaxial | 47.0 dB(A) | 0.350 in H2O (87.2 Pa) |
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
G3G146-AB54-01 ebm-papst Inc.
AC Blower Ball Bearing 230V 1.1A 175W 50Hz/60Hz 2520RPM Flange Mount
Price: 0.0000
RFQ -
-
-
-
RH35M-6/202667 ebm-papst Inc.
AC Motorized Impeller Ball Bearing 230V 130W 60Hz 1100CFM 59dB Flange Mount
Price: 0.0000
RFQ -
-




















Need Help?